Transmission electron microscopy

Sungwoo Sohn, PhD

About the instrument

While the software and electron optics share a great deal with the 200kV TEMs found in the Yale Medical School, the FEI Tecnai Osiris 200kV TEM is equipped with a new type of high-brightness electron source and a new high-area solid-angle x-ray detector, making possible high-speed spectral imaging. This new generation of electron microscope is operated from a remote console, making use of motorized apertures and high-resolution video cameras to keep human operators removed from the sensitive electron optics.

Transmission electron microscope

Available to Yale researchers & external researchers

Specifications

 

Point resolution 0.25 nm
Information limit0.14 nm
Spherical aber. coef.1.2 mm
Chromatic aber. coef.1.1 mm
Maximum tilt±30
Brightness @200kV1.8e9 A/cm²srad
EDX resolution136 eV

Rates

Rates in US$/hour unless otherwise noted

 Yale academicExternal academicIndustrial      
SEM, Hitachi3761215
AFM, Bruker3558105
e-beam, EBPG100165300
TEM, FEI Osiris100165300
Ion mill, Fischione 3761111
Ion mill, Hitachi3761111
Gold sputtering203276
Iridium sputtering203276
Microtome, Leica305090
HSQ resist, 4 ml25 ea41 ea75 ea
CSAR resist, 4 ml20 ea33 ea60 ea
Dektak profilometer101645

Training & services

We have recorded a set of video clips for TEM training. You will be at the TEM, watching and copying the videos, while the instuctor is nearby and available for questions. You will stop the videos at various times so that the instructor can check your progress. This seems to work pretty well, and people like going through the course at their own pace. You might take one hour, or you might take four hours. It’s up to you. Sign up for TEM training by using this appointment calendar. 

The hard part of TEM training is showing you how to use the load lock. But we found a way! The Gibbs shop made us a “load lock simulator” that lets you practice without abusing the vacuum pumps. Neat! 

Contact

Michael Rooks

Cheat sheets

TEM prep tools

In support of TEM sample preparation, the YINQE laboratory is also equipped with a Fischione 1050 ion-beam thinning tool, a focused ion-beam instrument, and a cryo-microtome.

Microtome

A microtome makes possible the sectioning of soft material for TEM analysis. Accessories for the Leica Ultra UC7 include a trimming mill and a glass knife maker.

Materials suitable for microtome slicing include polymer beads, carbon nanotubes, electro-spun fibers, and soft metals. YINQE supports only room-temperature operation.

More expertise in low-temperature sectioning and staining can be found at the Yale Medical School TEM facility.